Our Commitment to Quality

QUALITY CONTROL
IN STATE OF THE ART MANUFACTURING FACILITIES

Our manufacturing facilities implements quality control measures at all stages of the manufacturing process. Rigorous testing is carried out to meet the most stringent standards.

Our highly skilled and trained Quality Control staff ensures every facet of the manufacturing and operational proceses is continuously monitored as we operate 24 hours a day, 7 days a week, and 51 weeks a year.

Our finished products are subjected to extensive quality tests for colour consistency, physical properties and adherence to product specifications.

COLOUR CONSISTENCY

Cladding Wholesale’s strict quality control measures ensures the colour accuracy of each cladding board.

All colour pigments used in the production of Cladding Wholesale’s cladding products are digitally checked and precisely matched using digital colourimeters in modern laboratory facilities.

This quality control measure ensures the colour of each cladding board is accurately achieved for each production batch each time, ensuring a superior level of colour consistency.

COMMITMENT TO COMPLIANCE WITH AUSTRALIAN STANDARDS

National Construction Code (NCC) 2019 | Building Code of Australia (BCA) requires vinyl wall cladding used for new constructions comply to Australian standards.

Cladding Wholesale’s Colonial Vinyl Cladding has been tested to NCC 2019 standards.

Superb Quality Cladding

Colonial Vinyl Cladding
Tested to NCC 2019 standards

COMMITMENT TO QUALITY AND COMPLIANCE

COLONIAL VINYL CLADDING COMPLIANCE TESTING

Cladding Wholesale’s Colonial Vinyl Wall Cladding has been extensively tested to NCC 2019 | Building Code of Australia standards in laboratories approved by NATA (National Association of Testing Authorities).

Testing is carried out in Australian-based NATA laboratories, where tests are government approved, recommended and generally accepted with OECD mutual recognition.

Colonial Vinyl Cladding Successful Tests

NCC 2019
Fire Tests – BAL Rating


CLADDING WHOLESALE
COLONIAL INSULATED CLADDING

Passed all

Compliance requirements of a simulated bushfire attack in accordance with clause 14 & 15 of AS 1530.8.1:2018 for an external construction

  • NATA Approved Laboratory BAL Tests
  • Test result BAL-AA19




NCC 2019
Weatherproofing
Tests


CLADDING WHOLESALE
COLONIAL INSULATED CLADDING

Passed all

Compliance requirements of the NCC 2019 Weatherproofing methods V2.2.1 and FV1 in cyclonic regions C3.

  • Test procedures in accordance with Australian Standards AS/NZS4248:2008, Testing of Building Facades
  • NATA Approved Laboratory Weatherproofing tests
  • NCC 2019 Weatherproofing Verification Methods FV1 and V2.2.1

NCC 2019
Thermal Insulation Material


CLADDING WHOLESALE
COLONIAL INSULATED CLADDING

Passed all

Compliance requirements when evaluated in accordance with NCC 2019 Volume 2 AS/NZS 4859 Parts 1 & 2 to achieve:

  • Total Thermal Resistance, RTi = R3.24 Winter : R3.04 Summer
  • Corresponding Total Conductance, UTi = 0.31 w/(m2k) : 0.33 w/(m2k)


NCC 2019
Cyclic Wind Loading
Tests


CLADDING WHOLESALE
COLONIAL INSULATED CLADDING

TESTED SUITABLE

For use in Australian tropical cyclone areas
(Wind classification C3)

  • NATA Approved Laboratory Wind Loading Tests
  • Australian/New Zealand Standard AS1170 Part 2 – 2002 – AS4040.3 Cyclic Ultimate Wind Load tests
  • AS1562.1 Design and Installation
  • Testing Region C – Houses, elevated and ground level in all exposure conditions and other buildings up to 10 metres high (open rural) and 25 metres (suburban terrain)

NCC 2019
Accelerated Weathering, Colourfastness, Dimensional Stability


CLADDING WHOLESALE
COLONIAL INSULATED CLADDING

Passed all

Compliance requirements of AS4257.2 and AS4257.7

  • NATA Approved Laboratory Weathering Exposure Tests
  • Colourfastness – UV Exposure | AS4257.7
  • Dimensional Stability on Temperature Changes to 60°c | AS4257.2
  • Accelerated Weathering Exposure and Dimensional Stability Testing